Specifications

ACOUSTICAL1 | |
Operating Frequency Range2 | 30 Hz – 125 Hz |
Frequency Response3 | 32 Hz – 115 Hz ±4 dB |
Phase Response | 40 Hz – 110 Hz ±30° |
Linear Peak SPL4 | 133 dB with crest factor >10 dB (M-noise), 133 dB (Pink noise), 134.5 dB (B-noise) |
COVERAGE | |
360° (single unit); varies with number of units and configurations | |
TRANSDUCERS | |
Low Frequency | One 18-inch, dual-coil, long-excursion cone driver; 2Ω nominal impedance |
AUDIO INPUT | |
Type | Differential, electronically balanced |
Maximum Common Mode Range | ±15 V DC, clamped to earth for voltage transient protection |
Connectors5 | XLR 5-pin female input with male loop output; XLR 3-pin female connectors available to accommodate only balanced audio (no RMS signals) |
Input Impedance | 10 kΩ differential between pins 2 and 3 |
Wiring | Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamped network to provide virtual ground lift at audio frequencies Pin 2: Signal + Pin 3: Signal - Pin 4: RMS Pin 5: RMS Case: Earth ground and chassis |
Nominal Input Sensitivity | 6.0 dBV (2.0 V rms) continuous is typically the onset of limiting for noise and music |
Input Level | Audio source must be capable of producing +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker |
AMPLIFIER | |
Type | Two-channel, open-loop, class D |
Total Output Power6 | 3100 W peak |
THD, IM, TIM | < 0.02% |
Cooling | Convection |
AC POWER | |
Connectors | powerCON 20 input with loop output |
Automatic Voltage Selection | 90–265 V AC, 50–60 Hz |
Safety Rated Voltage Range | 100–240 V AC, 50–60 Hz |
Turn-on and Turn-off Points | 90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC |
CURRENT DRAW | |
Idle Current | 0.60 A rms (115 V AC), 0.49 A rms (230 V AC), 0.63 A rms (100 V AC) |
Maximum Long-Term Continuous Current (>10 sec) | 4.9 A rms (115 V AC); 2.5 A rms (230 V AC); 5.2 A rms (100 V AC) |
Burst Current (<1 sec)7 | 8.8 A rms (115 V AC), 4.7 A rms (230 V AC), 11.0 A rms (100 V AC) |
Maximum Instantaneous Peak Current | 18.2 A peak (115 V AC), 9.2 A peak (230 V AC), 20.6 A peak (100 V AC) |
Inrush Current | < 20 A peak |
RMS NETWORK | |
Equipped with two-conductor twisted-pair network, reporting all operating parameters of amplifiers to system operator’s host computer. | |
PHYSICAL | |
Dimensions without Rigging | W: 27.43 in (697 mm) x H: 24.43 in (621 mm) x D: 24.89 in (632 mm) |
Dimensions with Rigging | W: 27.47 in (698 mm) x H: 24.43 in (621 mm) x D: 24.89 in (632 mm) |
Weight without Rigging | 136 lb (61.7 kg) |
Weight with Rigging | 159 lb (72.1 kg) |
Enclosure | Premium multi-ply birch with slightly textured black finish |
Protective Grille | Powder-coated, hex-stamped steel with acoustical black mesh |
Rigging | Optional end frames with captive GuideALinks secured with 0.3125 in x 0.63 in quick release pins that allow 0°, 1.25°, 2.5°, 3.75°, or 5° splay angles; detachable side handles. Rigging supports ground-stacked, flown, and cardioid configurations. |
Pole Mount | U.S. version: 1.5 in (38 mm) E.U. version: 1.375 in (35 mm and M20 thread at the bottom) |
Notes

Loudspeaker system predictions for coverage and SPL are available in Meyer Sound's MAPP System Design Tool.
Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.
Measured in half-space with pink noise at 4 m, 1/3-octave frequency resolution.
Linear Peak SPL is measured in half-space at 4 m referred to 1 m. Loudspeaker SPL compression measured with M-noise at the onset of limiting, 2-hour duration, and 50-degree C ambient temperature is <2 dB.
M-noise is a full bandwidth, (10 Hz–22.5 kHz) test signal developed by Meyer Sound to better measure the loudspeaker’s music performance. It has a constant instantaneous peak level in octave bands, a crest factor that increases with frequency, and a full bandwidth Peak to RMS ratio of 18 dB. The presence of a greater-than (>) symbol with regard to crest factor indicates it may be higher depending on EQ and boundary loading.
Pink noise is a full bandwidth test signal with Peak to RMS ratio of 12.5 dB.
B-noise is a Meyer Sound test signal used to ensure measurements reflect system behavior when reproducing the most common input spectrum, and to verify there is still headroom over pink noise.
Pins 4 and 5 (RMS) only included with XLR 5-pin connector that accommodates both balanced audio and RMS signals.
Peak power based on the maximum unclipped voltage the amplifier will produce into the nominal load impedance.
AC power cabling must be of sufficient gauge so that under burst current rms conditions, cable transmission losses do not cause the loudspeaker’s voltage to drop below the specified operating range.