Specifications

ACOUSTICAL1 | |
Operating Frequency Range2 | 42 Hz – 22 kHz |
Frequency Response | 45 Hz – 20 kHz ± 4 dB |
Phase Response | 190 Hz – 20 kHz ±45° |
Linear Peak SPL3 | 120.5 dB with 18.5 dB crest factor (M-noise), 117.5 dB (Pink noise), 120 dB (B‑noise) |
COVERAGE | |
Horizontal Coverage | 80° |
Vertical Coverage | 50° |
TRANSDUCERS | |
Low Frequency | One 6.5‑inch long‑excursion cone driver; 4 Ω nominal impedance |
High Frequency | One 1‑inch dome tweeter on a constant‑directivity waveguide; 4 Ω nominal impedance |
AUDIO INPUT | |
Type | Differential, electronically balanced |
Maximum Common Mode Range | ±15 V DC |
Connectors | XLR 3‑pin female input with male loop output. |
Input Impedance | 10 kΩ differential between pins 2 and 3 |
Wiring | Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies Pin 2: Signal + Pin 3: Signal – Case: Earth ground and chassis |
Nominal Input Sensitivity | 6 dBV (2.0 V rms) continuous is typically the onset of limiting for noise and music |
Input Level | Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker. |
AMPLIFIER | |
Type | Two‑channel, Class‑D |
Total Output Power4 | 900 W peak |
THD, IM, TIM | < 0.02% |
Cooling | Convection |
AC POWER | |
Connector | powerCON 20 input with loop output (up to 7 Amie loudspeakers may be safely looped) |
Automatic Voltage Selection | 90–265 V AC |
Safety Agency Rated Voltage Range | 100–240 V AC, 50–60 Hz |
Turn‑on and Turn‑off Points | 90 V AC turn‑on, no turn‑off; internal fuse‑protection above 265 V AC |
CURRENT DRAW | |
Idle Current | 0.160 A rms (115 V AC); 0.144 A rms (230 V AC); 0.183 A rms (100 V AC) |
Maximum Long‑Term Continuous Current (>10 sec) | 0.68 A rms (115 V AC); 0.36 A rms (230 V AC); 0.79 A rms (100 V AC) |
Burst Current (<1 sec)5 | 1.02 A rms (115 V AC), 0.51 A rms (230 V AC), 1.2 A rms (100 V AC) |
Maximum Instantaneous Peak Current | 2.7 A peak (115 V AC), 1.4 A peak (230 V AC), 3.1 A peak (100 V AC) |
Inrush Current | <20.0 A peak |
PHYSICAL | |
Dimensions | W: 9.00 in (229 mm) x H: 15.30 in (389 mm) x D: 13.24 in (336 mm) |
Weight | 25 lb (11.3 kg) |
Enclosure | Premium multi‑ply birch, low‑gloss slightly textured black finish |
Rigging | 3/8‑inch ‑ 16 threaded side attachment points for optional mounting accessories |
Notes

Loudspeaker system predictions for coverage and SPL are available in Meyer Sound’s MAPP System Design Tool.
Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.
Linear Peak SPL is measured in free‑field at 4 m referred to 1 m. Loudspeaker SPL compression measured with M‑noise at the onset of limiting, 2‑hour duration, and 50 °C ambient temperature is <2 dB.
M-noise is a full bandwidth, (10Hz–22.5kHz) test signal developed by Meyer Sound to better measure the loudspeaker’s music performance. It has a constant instantaneous peak level in octave bands, a crest factor that increases with frequency, and a full bandwidth Peak to RMS ratio of 18 dB.
Pink noise is a full bandwidth test signal with Peak to RMS ratio of 12.5 dB.
B-noise is a Meyer Sound test signal used to ensure measurements reflect system behavior when reproducing the most common input spectrum, and to verify there is still headroom over pink noise.
Peak power based on the maximum unclipped peak voltage the amplifier will produce into the nominal load impedance.
AC power cabling must be of sufficient gauge so that under burst current rms conditions, cable transmission losses do not cause the loudspeaker’s voltage to drop below the specified operating range.