Skip to main content

Meyer Sound Documentation

Specifications
In this section:
meyer-blue-rule-line.png

ACOUSTICAL1

Operating Frequency Range2

28 Hz – 180 Hz

Frequency Response3

30 Hz – 160 Hz ±4 dB

Phase Response

45 Hz – 160 Hz ±30°

Linear Peak SPL4

140 dB with crest factor >9.5 dB (M-noise), 140 dB (Pink noise), 141 dB (B‑noise)

COVERAGE

360° (single unit); varies with number of units and configuration

TRANSDUCERS

Low Frequency

Two 18‑inch long‑excursion cone drivers; 8Ω nominal impedance

AUDIO INPUT

Type

Differential, electronically balanced

Maximum Common Mode Range

±15 V DC, clamped to earth for voltage transient protection

Connectors

XLR 3‑pin female input with male loop output

Input Impedance

10 kΩ differential between pins 2 and 3

Wiring

Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies

Pin 2: Signal + Pin 3: Signal –

Case: Earth ground and chassis

Nominal Input Sensitivity

0 dBV (1.0 V rms) continuous is typically the onset of limiting for noise and music

Input Level

Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker

AMPLIFIER

Type

Two‑channel complementary MOSFET output stages (Class AB/H bridged)

Total Output Power5

8100 W peak

THD, IM, TIM

< 0.02%

Cooling

Three ultra high‑speed primary fans; three ultra high‑speed reserve fans

AC POWER

Connectors

PowerCon32

Automatic Voltage Selection

208–235 V AC, 50–60 Hz

Safety Rated Voltage Range

208–235 V AC, 50–60 Hz

Turn‑on and Turn‑off Points

165 V AC turn‑on; 264 V AC turn‑off

CURRENT DRAW

Idle Current

0.6 A rms (230 V AC)

Maximum Long‑Term Continuous Current (>10 sec)

10.5 A rms (230 V AC)

Burst Current (<1 sec)6

18 A rms (230 V AC)

Maximum Instantaneous Peak Current

53 A peak (230 V AC)

Inrush Current

< 30 A peak

RMS NETWORK7

Equipped with an RMS network module; reports all operating parameters of amplifiers to system operator’s host computer via the RMServer hardware unit.7

PHYSICAL

Dimensions

W: 51.04 in (1296 mm) x H: 20.48 in (520 mm) x D: 33.00 in (838 mm)

Weight without Rigging

249 lb (112.9 kg)

Enclosure

Premium multi‑ply birch with slightly textured black finish

Protective Grille

Powder‑coated, hex‑stamped steel with acoustical black mesh

Notes
meyer-blue-rule-line.png
  1. Loudspeaker system predictions for coverage and SPL are available in Meyer Sound's MAPP System Design Tool.

  2. Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.

  3. Measured in half‑space at 4 m, 1/3‑octave frequency resolution.

  4. Linear Peak SPL is measured in half‑space at 4 m referred to 1 m. Loudspeaker SPL compression measured with M‑noise at the onset of limiting, 2‑hour duration, and 50 °C ambient temperature is < 2 dB.

    M-noise is a full bandwidth, (10 Hz–22.5 kHz) test signal developed by Meyer Sound to better measure the loudspeaker’s music performance. It has a constant instantaneous peak level in octave bands, a crest factor that increases with frequency, and a full bandwidth Peak to RMS ratio of 18 dB. The presence of a greater‑than (>) symbol with regard to crest factor indicates it may be higher depending on EQ and boundary loading.

    Pink noise is a full bandwidth test signal with Peak to RMS ratio of 12.5 dB.

    B-noise is a Meyer Sound test signal used to ensure measurements reflect system behavior when reproducing the most common input spectrum, and to verify there is still headroom over pink noise.

  5. Peak power based on the maximum unclipped voltage the amplifier will produce into the nominal load impedance.

  6. AC power cabling must be of sufficient gauge so that under burst current rms conditions, cable transmission losses do not cause the loudspeaker’s voltage to drop below the specified operating range.