Skip to main content

Meyer Sound Documentation

Specifications
In this section:
meyer-blue-rule-line.png

ACOUSTICAL1

Operating Frequency Range2

37 Hz – 18 kHz

Frequency Response3

38 Hz – 17 kHz ±4 dB

Phase Response

230 Hz – 17 kHz ±30°

Linear Peak SPL4

128 dB with 18 dB crest factor (M-noise), 125.5 dB (Pink noise), 129 dB (B-noise)

COVERAGE

Horizontal Coverage

80°

Vertical Coverage

50°

TRANSDUCERS

Low Frequency

12-inch cone driver; 2 Ω nominal impedance

High Frequency

4-inch diaphragm compression driver; 8 Ω nominal impedance

AUDIO INPUT

Type

Differential, electronically balanced

Maximum Common Mode Range

±5 V DC, clamped to earth for voltage transient protection

Connectors

3-pin XLR female input with male loop output

Input Impedance

10 kΩ differential between pins 2 and 3

Wiring

Pin 1: Chassis/earth through 1 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies

Pin 2: Signal + Pin 3: Signal –

Case: Earth ground and chassis

Nominal Input Sensitivity

10 dBV (3.2 V rms) continuous is typically the onset of limiting for noise and music

Input Level

Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker.

AMPLIFIER

Type

Two channel, Class-D

Total Output Power5

1400 W peak

THD, IM, TIM

< 0.02%

Cooling

Convection, with recessed heat sink

AC POWER

Connector

powerCON 20 input with loop output

Automatic Voltage Selection

90–265 V AC

Safety Rated Voltage Range

100–240 V AC, 50–60 Hz

Turn-on and Turn-off Points

90 V AC turn-on, no turn-off; internal fuse-protection above 265 V AC

CURRENT DRAW

Idle Current

0.23 A rms (115 V AC); 0.19 A rms (230 V AC); 0.24 A rms (100 V AC)

Maximum Long-Term Continuous Current (>10 sec)

1.58 A rms (115 V AC); 0.83 A rms (230 V AC); 1.78 A rms (100 V AC)

Burst Current (<1 sec)6

3.1 A rms (115 V AC); 1.4 A rms (230 V AC); 3.6 A rms (100 V AC)

Maximum Instantaneous Peak Current

12.0 A peak (115 V AC); 8.0 A peak (230 V AC); 12.4 A peak (100 V AC)

Inrush Current

25 A peak (115 V AC); 54 A peak (230 V AC); 20 A peak (100 V AC)

RMS NETWORK (OPTIONAL)

Two-conductor twisted-pair network that reports all operating parameters of amplifiers to system operator’s host computer.

PHYSICAL

Dimensions

W: 19.00 in (483 mm) x H: 25.38 in (645 mm) x D: 14.96 in (380 mm)

Weight

76 lb (34.5 kg)

Enclosure

Premium multi-ply birch with slightly textured black finish

Protective Grille

Attachment points on cabinet front corners for optional grille frame with black cloth

Rigging

Two threaded M6 attachment points on cabinet bottom for optional MYA-DES cradle-style yoke

Notes
meyer-blue-rule-line.png
  1. Loudspeaker system predictions for coverage and SPL are available in Meyer Sound’s MAPP System Design Tool.

  2. Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.

  3. Free-field, measured with 1/3 octave frequency resolution at 4 m.

  4. Linear Peak SPL is measured in free-field at 4 m referred to 1 m. Loudspeaker SPL compression measured with M-noise at the onset of limiting, 2-hour duration, and 50 °C ambient temperature is < 2 dB.

    M-noise is a full bandwidth (10 Hz–22.5 kHz) test signal developed by Meyer Sound to better measure the loudspeaker’s music performance. It has a constant instantaneous peak level in octave bands, a crest factor that increases with frequency, and a full bandwidth Peak to RMS ratio of 18 dB.

    Pink noise is a full bandwidth test signal with Peak to RMS ratio of 12.5 dB.

    B-noise is a Meyer Sound test signal used to ensure measurements reflect system behavior when reproducing the most common input spectrum, and to verify there is still headroom over pink noise.

  5. Peak power based on the maximum unclipped peak voltage the amplifier will produce into the nominal load impedance.

  6. AC power cabling must be of sufficient gauge so that under burst current rms conditions, cable transmission losses do not cause the loudspeaker’s voltage to drop below the specified operating range.