Specifications

FRONT PANEL | |
LEDs per channel | Eight blue LEDs to indicate presence of output voltage Eight green LEDs to indicate load current |
REAR PANEL | |
Audio Input | Eight male 3-pin Phoenix connectors Seven Link Switches |
Channel Output | Eight male 5-pin Phoenix connectors |
Output Wiring | Two pins for DC power, three pins for balanced audio Pin 1: 48 V DC - (chassis/earth ground) Pin 2: 48 V DC + Pin 3: Audio shield/chassis/earth ground Pin 4: Signal - Pin 5: Signal + |
Output Voltage1 | 48 V DC per channel (with intelligent circuit protection against surges and shorts) |
AC POWER | |
AC Connector | Neutrik powerCON TRUE1 TOP (True Outdoor Protection) |
Voltage Selection | Automatic |
Safety Rated Voltage Range | 100–240 V AC; 50–60 Hz; 1350 W maximum |
TELEMETRY | |
Via the “Monitoring” RJ45 connector, standard Ethernet network connection to computer running Meyer Sound’s Nebra software, includes Wink/identify and mute functions, reports power supply temperature and fan speed, voltage and current values for each output channel. | |
PHYSICAL | |
Dimensions | 1RU in height; W: 19.00 in (483 mm) x H: 1.73 in (44 mm) x D: 16.22 in (412 mm) |
Weight | 15.1 lb (6.9 kg) |
ENVIRONMENTAL | |
Operating Temperature | From 32 °F (0 °C) to 113 °F (45 °C) |
Non-operating Temperature | Below -40 °F (-40 °C), above 167 °F (75 °C) |
Humidity | Up to 95% at 35 °C |
Operating Altitude | Up to 5000m (16,000 ft) |
Non-operating Altitude | Above 12,000 m (39,000 ft) |
Notes

Supports NEC Class 2 wiring.