The ULTRA-X40/42 loudspeaker combines advanced loudspeaker technology with equally advanced power capabilities. Understanding power distribution, voltage and current requirements, and electrical safety guidelines is critical for the safe operation of the ULTRA-X40/42.

AC Power Distribution
meyer-blue-rule-line.png

All components in an audio system (self-powered loudspeakers, mixing consoles, and processors) must be properly connected to an AC power distribution system, ensuring that AC line polarity is preserved and that all grounding points are connected to a single node or common point using the same cable gauge (or larger) as the neutral and line cables.

Caution

  • Make sure the voltage received by the ULTRA-X40/42 loudspeaker remains within its 90–264 V AC operating range. In addition, the ground line must always be used for safety reasons and the line-to-ground voltage should never exceed 250 V AC (typically 120 V AC from line to ground).

  • Before applying AC power to any Meyer Sound self-powered loudspeaker, make sure that the voltage potential difference between the neutral and earth-ground lines is less than 5 V AC when using single-phase AC wiring.

Note

Improper grounding of connections between loudspeakers and the rest of the audio system may produce noise or hum, or cause serious damage to the input and output stages of the system’s electronic components.

120V AC, 3-Phase Wye System (Single Line) -- Line-Neutral-Earth/Ground
meyer-blue-rule-line.png

The figure below illustrates a basic 120 V AC, 3-phase Wye distribution system with the loudspeaker load distributed across all three phases, with each loudspeaker connected to a single line and common neutral and earth/ground lines. This system delivers 120 V AC to each loudspeaker.

120-3-phase-single-line-L-N-E.ai

120 V AC, 3-Phase Wye System (Single Line to Loudspeakers)

120V AC, 3-Phase Wye System (Two Lines) -- Line-Line-Earth/Ground
meyer-blue-rule-line.png

The figure below illustrates a 120 V AC, 3-phase Wye distribution system with each loudspeaker connected to two lines and a common earth/ground line. This configuration is possible because ULTRA-X40/42 tolerates elevated voltages from the ground line and does not require a neutral line. This system delivers 208 V AC to each loudspeaker.

120-3-phase-two-line-L-L-E.ai

120 V AC, 3-Phase Wye System (Two Lines to Loudspeakers)

Tip

The 120 V AC, 3-phase Wye system with two lines is recommended because it allows loudspeakers to draw less current than with single-line systems, thereby reducing voltage drop due to cable resistance. It also excludes the potential of varying ground to neutral voltages producing an audible hum.

230V AC, 3-Phase Wye System (Single Line) -- Line-Neutral-Earth/Ground
meyer-blue-rule-line.png

The figure below illustrates a basic 230 V AC, 3-phase Wye distribution system with the loudspeaker load distributed across all three phases, with each loudspeaker connected to a single line and common neutral and earth/ground lines. This system delivers 230 V AC to each loudspeaker.

230-3-phase-single-line-L-N-E.ai

230 V AC, 3-Phase Wye System (Single Line to Loudspeakers)

Caution

For 230 V AC, 3-phase Wye systems, never connect two lines to the AC input of ULTRA-X40/42, as the resulting voltage would exceed the upper voltage limit (275 V AC) and will damage the loudspeaker.

AC CONNECTORS
meyer-blue-rule-line.png

The ULTRA-X40/42 user panel includes two powerCON 20 connectors one for AC Input (blue) and one for AC Loop Output (gray), as shown in the figure below.

ultra-x40-AC.jpg

AC Input (Left) and AC Loop Output (Right) Connectors

AC Input (Blue)
meyer-blue-rule-line.png

The blue AC Input connector supplies power to ULTRA-X40/42. The 3-conductor powerCON 20 is rated at 20 A and uses a locking connector that prevents accidental disconnections. A 10-foot AC power cable, rated at 15 A, is included with each loudspeaker. If the included AC power cable is replaced, make sure to use a cable with the appropriate power plug (on the other end) for the region where the unit will be operated. ULTRA-X40/42 requires a grounded outlet. To operate safely and effectively, it is extremely important that the entire system be properly grounded.

The AC Input connector also supplies power to any additional loudspeakers connected to the loudspeaker’s gray Loop Output connector.

Caution

When looping AC power for loudspeakers, do not exceed the current capability of the AC Input connector (20 A) or the included AC power cable (15 A). Consider the total current draw for all loudspeakers on the circuit, including the first loudspeaker.

AC Loop Output (Gray)
meyer-blue-rule-line.png

The gray AC Loop Output connector allows multiple ULTRA-X40/42 to be looped and powered from a single power source. The 3-conductor powerCON 20 is rated at 20 A and uses a locking connector that prevents accidental disconnections. For applications that require multiple ULTRA-X40/42, connect the AC Loop Output of the first loudspeaker to the AC Input of the second loudspeaker, and so forth.

The maximum number of loudspeakers that can be looped from the AC Loop Output connector is determined by the voltage of the power source, the current draw of the looped loudspeakers, the circuit breaker rating, and the rating of the AC power cable connected to the first ULTRA-X40/42 loudspeaker, as described in the table below.

Table 1. Maximum ULTRA-X40/42s that Can Be Looped with AC Power

Circuit Breaker/ Connector Rating

115 V AC

230 V AC

100 V AC

15 A

6 looped

(7 total)

13 looped

(14 total)

5 looped

(6 total)

20 A

9 looped

(10 total)

18 looped

(19 total)

8 looped

(9 total)



Note

Current draw for ULTRA-X40/42 is dynamic and fluctuates as operating levels change. The indicated number of loudspeakers that can be looped assumes that operating levels are normal and not such that loudspeakers are constantly limiting.

ULTRA-X40/42 ships with a gray powerCON 20 cable mount connector, rated at 20 A, for assembling AC looping cables. Assembled 1-meter AC looping cables (PN 28.115.032.03) are also available from Meyer Sound.

Wiring AC Power Cables
meyer-blue-rule-line.png

ULTRA-X40/42 ships with a gray powerCON 20 cable mount connector, rated at 20 A, for assembling AC looping cables, as shown in the figure below. The pins on the powerCON 20 cable mount connector are labeled as follows:

  • L (Line)

  • N (Neutral)

  • PE (Protective Earth or Ground)

powercon-20.jpg

powerCON20Cable Mount Connector

How AC power cables are wired is determined by the type of AC power distribution system used (seeAC Power Distribution). When wiring AC power cables for single-line systems, use one of the wiring schemes shown in the figure below and described in the table below:

us-europe-wiring.jpg

AC Wiring Scheme

Table 2. Wiring Scheme

Wire Color

Attach to the Following Terminal

U.S. / Canada 60Hz

European 50Hz

Black

Brown

Hot or live (L)

White

Blue

Neutral (N)

Green

Green and Yellow

Protective earth / ground (E or PE)



Caution

When wiring AC power cables and distribution systems, it is important to preserve AC line polarity and connect the earth ground at both ends of the cable. ULTRA-X40/42 requires a grounded connection. Always use a grounded outlet and plug. It is extremely important that the system be properly grounded to operate safely and properly. Do not ground-lift the AC cable.

Voltage Requirements
meyer-blue-rule-line.png

ULTRA-X40/42 operates as intended when receiving AC voltage within the following range:

  • 90–264VAC, 50–60Hz

If the voltage drops below 90V, the loudspeaker uses stored power to continue operating temporarily; the loudspeaker powers off if the voltage does not return to its operating range.

If the voltage rises above 275V, the power supply could become damaged.

Caution

The power source for ULTRA-X40/ 42 should always operate within the required operating range, at least a few volts from the upper and lower limits. This approach ensures that AC voltage variations from the service entry—or peak voltage drops due to cable runs—will not cause the loudspeaker’s amplifier to cycle on and off or cause damage to the power supply.

Current Requirements
meyer-blue-rule-line.png

Current draw for loudspeakers is dynamic and fluctuates as operating levels change. Because different cables and circuit breakers heat up at varying rates, it is important to understand the following types of current ratings and how they affect circuit breaker and cable specifications.

  • Idle Current — The maximum rms current during idle periods.

  • Maximum Long-Term Continuous Current — The maximum rms current during a period of at least 10 seconds. The maximum long-term continuous current is used to calculate temperature increases for cables and to ensure that the size and gauge of each cable conforms to electrical code standards. This current rating is also used to select appropriately rated, slow-reacting thermal breakers, which are recommended for loudspeaker power distribution. In addition, the maximum long-term continuous current can be used to calculate the AC looping capability for ULTRA-X40/42 loudspeakers.

  • Burst Current — The maximum rms current during a period of around 1 second. The burst current is used as a rating for magnetic breakers. It is also used for calculating the peak voltage drop in long AC cable runs according to the following formula:

    V pk (drop) = I pk x R (cable total)

  • Maximum Instantaneous Peak Current — A rating for fast-reacting magnetic breakers.

Use the information in Table 3 to select the appropriate cable gauge and circuit breaker ratings for the system’s operating voltage.

Table 3. For best performance, the AC cable voltage drop should not exceed 10V (10percent at 115V and 5percent at 230V). This approach ensures that the AC voltage variations from the service entry— or peak voltage drops due to longer cable runs—do not cause the amplifier to cycle on and off.

Current Draw

115V AC

230V AC

100V AC

Idle

0.27Arms

0.25 A rms

0.29 A rms

Maximum Long-Term Continuous

1.9Arms

1.0 A rms

2.2 A rms

Burst

3.1Arms

1.5 A rms

3.4 A rms

Maximum Instantaneous Peak

6.9Apeak

3.4 A peak

7.9 A peak



The minimum electrical service amperage required by a loudspeaker system is the sum of the maximum long-term continuous current for all loudspeakers. An additional 30 percent above the combined Maximum Long-Term Continuous amperages is recommended to prevent peak voltage drops at the service entry.

Note

For best performance, the AC cable voltage drop should not exceed 10V (10 percent at 115V and 5percent at 230V). This approach ensures that the AC voltage variations from the service entry— or peak voltage drops due to longer cable runs—do not cause the amplifier to cycle on and off.

Intelligent AC Power Supply
meyer-blue-rule-line.png

ULTRA-X40/42’s IntelligentAC™ power supply automatically selects the correct operating voltage (allowing the loudspeaker to be used internationally without manually setting voltage switches), eliminates high inrush currents with soft-start power up, suppresses high-voltage transients up to several kilovolts, filters common mode and differential mode radio frequencies (EMI), and sustains operation temporarily during low-voltage periods.

Powering on ULTRA-X40|42
meyer-blue-rule-line.png

When powering on ULTRA-X40/42, the following startup events take place over several seconds.

  1. Audio output is muted.

  2. Voltage is detected and the power supply mode is automatically adjusted as necessary.

  3. The power supply ramps up.

  4. On the user panel, the On/Status LED flashes multiple colors successively.

  5. The On/Status LED turns solid green, indicating the loudspeaker is unmuted and ready to output audio.

Caution

If the On/Status LED does not turn solid green, or the ULTRA-X40/42 does not output audio after 10 seconds, remove AC power immediately and verify that the voltage is within the required range. If the problem persists, contact Meyer Sound Technical Support.

Electrical Safety Guidelines
meyer-blue-rule-line.png

Make sure to observe the following important electrical and safety guidelines.

  • The powerCON 20 connector should not be engaged or disengaged when under load or energized. Either de-energize or disconnect the other end of the cable.]

  • ULTRA-X40/42 requires a grounded outlet. Always use a grounded outlet and plug.

    Edison_Plug_and_Duplex.ai
  • Do not use a ground-lifting adapter or cut the AC cable ground pin.

  • Do not exceed the current capability of the 20A AC Input connector for the loudspeaker. When looping loudspeakers, consider the total current draw for all loudspeakers on the circuit, including the first loudspeaker.

    g_grounding_color.ai
  • Make sure the AC power cable for the loudspeaker has the appropriate power plug (on the other end) for the area in which you will operate the loudspeaker. In addition, the AC power cable must be rated for the total current draw of all loudspeakers looped from the power source.

  • Do not operate the unit if the power cable is frayed or broken.

  • Keep all liquids away from ULTRA-X40/42 loudspeakers to avoid hazards from electrical shock.