ACOUSTICAL1

Operating Frequency Range2

20 Hz – 200 Hz

Frequency Response3

23 Hz – 160 Hz ±4 dB

Phase Response

32 Hz – 175 Hz ±30°

Linear Peak SPL4

127.5 dB with crest factor > 11.5 dB (M-noise), 127.5 dB (Pink noise), 131.5 dB (B‑noise)

COVERAGE

Varies with number of units and configuration

TRANSDUCERS

Low Frequency

One 18 in long‑excursion cone driver; 4 Ω nominal impedance

AUDIO INPUT

Type

Differential, electronically balanced

Maximum Common Mode Range

±15 V DC, clamped to earth for voltage transient protection

Connectors

XLR 3‑pin female input with male loop output

Input Impedance

10 kΩ differential between pins 2 and 3

Wiring

Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual ground lift at audio frequencies

Pin 2: Signal + Pin 3: Signal –

Case: Earth ground and chassis

Pad Switch

Normal position: no effect; Pad position: ‑7.5 dB input pad added to reduce upstream noise when loudspeaker is in close proximity to listeners

Nominal Input Sensitivity

0 dBV (1.0 V rms) continuous is typically the onset of limiting for noise and music

Input Level

Audio source must be capable of producing of +20 dBV (10 V rms) into 600 Ω to produce the maximum peak SPL over the operating bandwidth of the loudspeaker.

AMPLIFIER

Type

Single channel

Total Output Power5

900 W peak

THD, IM, TIM

< 0.02%

Cooling

Convection

AC POWER

Connector

powerCON 20 input with loop output

Automatic Voltage Selection

90–265 V AC

Safety Rated Voltage Range

100–240 V AC, 50–60 Hz

Turn‑on and Turn‑off Points

90 V AC turn‑on, no turn‑off; internal fuse‑protection above 265 V AC

CURRENT DRAW

Idle Current

0.26 A rms (115 V AC); 0.16 A rms (230 V AC); 0.30 A rms (100 V AC)

Maximum Long‑Term Continuous Current (>10 sec)

1.4 A rms (115 V AC); 0.7 A rms (230 V AC); 1.6 A rms (100 V AC)

Burst Current (<1 sec)6

2.7 A rms (115 V AC); 1.1 A rms (230 V AC); 3.0 A rms (100 V AC)

Maximum Instantaneous Peak Current

9 A peak (115 V AC); 6 A peak (230 V AC); 10 A peak (100 V AC)

Inrush Current

10 A peak (115 V AC); 8 A peak (230 V AC); 10 A peak (100 V AC)

RMS NETWORK (OPTIONAL)

Two‑conductor twisted‑pair network module: reports all operating parameters of amplifiers to system operator’s host computer via the RMServer hardware unit7.

PHYSICAL

Dimensions

W: 31.00 in (787 mm) x H: 20.65 in (525 mm) x D: 20.79 in (528 mm)

Weight

85 lb (38.6 kg)

Enclosure

Premium multi‑ply birch with slightly textured black finish

Protective Grille

Optional grille frame with black cloth

Notes
meyer-blue-rule-line.png
  1. Loudspeaker system predictions for coverage and SPL are available in Meyer Sound’s MAPP System Design Tool.

  2. Recommended maximum operating frequency range. Response depends on loading conditions and room acoustics.

  3. Measured in half‑space at 4 m, 1/3 octave frequency resolution.

  4. Linear Peak SPL is measured in half‑space at 4 m referred to 1 m. Loudspeaker SPL compression measured with M‑noise at the onset of limiting, 2‑hour duration, and 50 °C ambient temperature is < 2 dB.

    M-noise is a full bandwidth (10 Hz–22.5 kHz) test signal developed by Meyer Sound to better measure the loudspeaker’s music performance. It has a constant instantaneous peak level in octave bands, a crest factor that increases with frequency, and a full bandwidth Peak to RMS ratio of 18 dB. The presence of a greater‑than (>) symbol with regard to crest factor indicates it may be higher depending on EQ and boundary loading.

    Pink noise is a full bandwidth test signal with Peak to RMS ratio of 12.5 dB.

    B-noise is a Meyer Sound test signal used to ensure measurements reflect system behavior when reproducing the most common input spectrum, and to verify there is still headroom over pink noise.

  5. Peak power based on the maximum unclipped peak voltage the amplifier will produce into the nominal load impedance.

  6. AC power cabling must be of sufficient gauge so that under burst current rms conditions, cable transmission losses do not cause the loudspeaker’s voltage to drop below the specified operating range.

  7. RMServer hardware unit required and sold separately.